Masimo MightSat Rx Fingertip Pulse Oximeter with Bluetooth LE
The MightySat Rx Fingertip Pulse Oximeter is an easy to use, noninvasive device that measures and displays arterial oxygen saturation (SpO2), Pulse Rate (PR), and Perfusion Index (Pi).
Measures unique parameters and indicators
- SpO2 and PR featuring Masimo Signal Extraction Technology (SET)
- Perfusion Index - A measure of the dynamic changes in the perfusion index (Pi) that occur during the respiratory cycle
- Pleth Waveform - Real-time graphical representation of changes in volume of arterial blood with each pulse
- Signal I.Q - A measure of respiration rate based on changes in the plethysmographic waveform
Designed for performance
- Rotating and adjustable color screen for real-time display of all measurements
- Touchpad providing easy access to settings and device features
- Flexible finger pad that easily conforms to finger shape for enhanced comfort and enables secure application to minimize external interference
- Durable, lightweight design for use in clinical and home-care environments
Easy to use, two step instructions deliver results in an instance. Simply place the sensor on your finger and obtain the measurements.
Kit includes: MightySat Rx device, lanyard, batteries, and carrying case
DISPLAY RANGE
Functional Oxygen Saturation (SpO2). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0–100%
Pulse Rate (PR). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25–240 bpm
Perfusion Index (Pi). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0.02–20%
ACCURACY – (ARMS)
Oxygen Saturation (%SpO2) Accuracy Range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 70–100%
No Motion. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2%
Motion. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3%
Low Perfusion. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2%
Pulse Rate (PR) Accuracy Range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25–240 bpm
No Motion. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 bpm
Motion. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 bpm
Low Perfusion. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 bpm
PATIENT WEIGHT
Adult and Pediatric Patients. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . >30 kg (66 lbs)
MEASUREMENT RESOLUTION
Oxygen Saturation (%SpO2). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1%
Pulse Rate (PR) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 bpm
ENVIRONMENTAL
Operating Temperature. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 to 40˚ C (41 to 104˚ F)
Storage Temperature. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . -40 to 70˚ C (-40 to 158˚ F)
Operating Humidity. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 to 95%, non-condensing
Atmospheric Pressure. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 540 to 1060 mBar
PHYSICAL CHARACTERISTICS
Weight with Battery. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 73 g (0.16 lbs)
Dimensions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7.4 cm x 4.1 cm x 3.0 cm (2.9” x 1.6” x 1.2”)
ALARMS
No alarms on this product
CLASSIFICATION PER IEC 60601-1
EMC Classification. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Class B
Degree of Protection. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Type BF-Applied Part
Enclosure Degree of Ingress Protection. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . IP23
Mode of Operation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Continuous Operation
COMPLIANCE
Safety. . . . . . . . . . . . . . . . . . . . . . UL 60601-1, CSA C22.2 No. 601.1, IEC 60601-1, EN 60601-1
EMC. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . EN 60601-1-2, Class B
Pulse Oximeter. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ISO 80601-2-61
Conformity to EU MDD 93/42/EEC. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . CE Marked
BATTERY
Operating. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Two 1.5 Volt AAA Batteries
Battery. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Approximately 1800 spot-checks
COMMUNICATION
Radio Modes. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Bluetooth LE
Communication Compliance
Canada. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . IC: 7362A-MSAT01A
RSS-210
Europe. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . EN 300 328
EN 302 489-17